RPA Multiplex Basic Lyophilized Kit (Gen-4)
$1,276.00 - $8,294.00
All products have special prices for bulk purchase, please contact for more details if required.
Cat. No.: RMIB4-96 (for 96T)
Cat. No.: RMIB4-960 (for 960T)
Description
The RPA Multiplex Basic Lyophilized Kit (Gen-4) is designed for rapid, multiplex nucleic acid amplification using recombinase polymerase amplification (RPA). The optimized reaction system supports the simultaneous amplification of 2–4 targets in approximately 10–20 minutes, providing a flexible solution for molecular assay development.
With integrated reverse transcription (RT) capability, the kit supports the detection of both DNA and RNA targets. Its lyophilized formulation facilitates reagent handling and transportation under specified conditions.
A minimum detection limit of 400 copies/mL has been demonstrated across multiple validated targets under specific assay conditions. Available in 96-reaction and 960-reaction formats, the kit provides a versatile foundation for multiplex molecular detection research.
Key Features
Multiplex Amplification
Supports simultaneous amplification of 2–4 targets, depending on primer design and assay optimization.
DNA and RNA Target Detection
Integrated reverse transcription enables RNA target detection through reverse transcription followed by RPA amplification.
Rapid Amplification
The amplification reaction can be completed in approximately 10–20 minutes. Total assay time may vary depending on sample preparation and downstream detection.
Lyophilized Formulation
The freeze-dried reagent format supports convenient handling and transportation under specified storage conditions.
Validated Analytical Sensitivity
A minimum detection limit of 400 copies/mL has been demonstrated across multiple validated targets under specific assay conditions. Actual performance depends on the target, sample matrix, and assay configuration.
Flexible Assay Development
Designed for integration into compatible molecular detection workflows using suitable downstream detection methods.
Specifications | |
|---|---|
Parameter
| Specification
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Frequently Asked Questions
1. Can this kit be used for both DNA and RNA detection?
Yes. The kit incorporates reverse transcription capability, enabling RNA target detection through reverse transcription followed by RPA amplification, in addition to DNA target amplification.
2. How many targets can be amplified simultaneously?
The kit supports multiplex amplification of 2–4 targets. Reliable multiplex performance depends on primer compatibility, target characteristics, and assay optimization.
3. What is the detection limit?
A minimum detection limit of 400 copies/mL has been demonstrated across multiple validated targets under specific assay conditions. Performance may vary depending on the target, sample matrix, and assay configuration.
4. Which detection methods are supported?
The Basic kit is intended as a basic amplification reagent system for compatible molecular detection workflows. The appropriate downstream detection method and required components should be selected according to the intended assay.
5. How long does the amplification reaction take?
The amplification reaction typically takes approximately 10–20 minutes. Sample preparation and downstream detection may add to the total assay time.
6. Are the reagents ready to use directly from the package?
The reagents are supplied in separate lyophilized containers and require preparation before use. Please refer to the product instructions for the recommended reconstitution procedure and reaction setup.
Need Technical Assistance?
For information about primer compatibility, multiplex assay development, lateral flow detection, or bulk orders, please contact our technical team.
One More Thing
Based on our leading RPA technology, we have developed a series of reagent kits to enrich the field of POCT.
| No. | Name | Method | Sample | Process | Lowest Detection Limit (LOD) |
|---|---|---|---|---|---|
| 1 | Tuberculosis Complex Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Tongue swab | Nucleic acid release/direct amplification | 500 copies/mL |
2 | Type A Influenza Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Throat and nasal swab | Nucleic acid release/direct amplification | 500 copies/mL |
3 | Type B Influenza Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Throat and nasal swab | Nucleic acid release/direct amplification | 500 copies/mL |
4 | Type A/B Influenza Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Throat and nasal swab | Nucleic acid release/direct amplification | 500 copies/mL |
| 5 | Mycoplasma pneumoniae Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Throat and nasal swab | Nucleic acid release/direct amplification | 500 copies/mL |
6 | Cytomegalovirus A/B Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Throat and nasal swab | Nucleic acid release/direct amplification | 500 copies/mL |
7 | Chlamydia trachomatis/Neisseria gonorrhoeae Combined Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Vaginal swab | Nucleic acid release/direct amplification | 500 copies/mL |
8 | Human Immunodeficiency Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Whole blood | Nucleic acid release/direct amplification | 500 copies/mL |
9 | Chlamydia trachomatis Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Vaginal swab | Nucleic acid release/direct amplification | 500 copies/mL |
10 | Neisseria gonorrhoeae Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Vaginal swab | Nucleic acid release/direct amplification | 500 copies/mL |
11 | Human Papillomavirus 15 High-Risk Type Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Vaginal swab | Nucleic acid release/direct amplification | 500 copies/mL |
12 | African Swine Fever Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Oral, nasal, and eye swab | Nucleic acid release/direct amplification | 500 copies/mL |
13 | Rabies Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Oral, nasal, and eye swab, whole blood | Nucleic acid release/direct amplification | 500 copies/mL |
| 14 | Brucella Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Oral, nasal, and eye swab | Nucleic acid release/direct amplification | 500 copies/mL |
15 | Canine Distemper Virus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Oral, nasal, and eye swab | Nucleic acid release/direct amplification | 500 copies/mL |
| 16 | Canine Parvovirus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Oral, nasal, and eye swab | Nucleic acid release/direct amplification | 500 copies/mL |
| 17 | Canine Adenovirus Rapid Amplification Kit (with internal reference) | Real-time fluorescence/paper strip | Oral, nasal, and eye swab | Nucleic acid release/direct amplification | 500 copies/mL |
Related:
- Gen-1: RPA Basic Kit (Gen-1), RPA RT Basic Kit (Gen-1), RPA Fluorescent Kit (Gen-1), RPA RT Fluorescent Kit (Gen-1)
- Gen-2: RPA Basic Kit (Gen-2), RPA RT Basic Kit (Gen-2), RPA Fluorescent Kit (Gen-2), RPA RT Fluorescent Kit (Gen-2)
- Gen-3: RPA Basic Kit (Gen-3), RPA RT Basic Kit (Gen-3), RPA Fluorescent Kit (Gen-3), RPA RT Fluorescent Kit (Gen-3)
- Gen-4: RPA Multiplex Basic Lyophilized Kit (Gen-4), RPA Multiplex Fluorescent Lyophilized Kit (Gen-4)
- Lateral Flow Assay for RPA
Only for research and not intended for treatment of humans or animals